Heating boilers

Bosch Gaz 6000 WBN-24C RN

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 192 ;m2; Useful power: 24 ;kW; The combustion chamber: closed (turbocharged); Food: single-phase (220 V); Min. t of the heating system: 40 ;°C; Max. t of the heating system: 85 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Max. the pressure in the DHW circuit: 10 ;bar; Min. t hot water: 40; Max. t hot water: 60; Performance (Δt=25°C): 11.4 ;l/min; Summer operation: +; Efficiency: 93.2 ;%; Nominal pressure inlet gas: 16 ;mbar; Max. the gas flow: 2.8 ;m3/hour; The capacity of the surge...

BAXI Eco Four 24 F

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 180 ;m2; Useful power: 24 ;kW; The combustion chamber: closed (turbocharged); Food: single-phase (220 V); Power consumption: 130 ;W; Min. t of the heating system: 30 ;°C; Max. t of the heating system: 85 ;°C; Max. the pressure in the DHW circuit: 8 ;bar; Min. t hot water: 35; Max. t hot water: 60; Performance (Δt=25°C): 13.7 ;l/min; Summer operation: +; Mode "warm floors": +; Efficiency: 92.9 ;%; Nominal pressure inlet gas: 20 ;mbar; The capacity of the surge tank: 6 ;l; The pressure of the...

BAXI LUNA-3 Comfort 240 Fi

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 188 ;m2; Useful power: 25 ;kW; The combustion chamber: closed (turbocharged); Food: single-phase (220 V); Power consumption: 135 ;W; Min. t of the heating system: 30 ;°C; Max. t of the heating system: 85 ;°C; Max. the pressure in the DHW circuit: 8 ;bar; Min. t hot water: 35; Max. t hot water: 65; Performance (Δt=25°C): 14.3 ;l/min; Performance (Δt=35°C): 10.2 ;l/min; Remote control unit: +; Summer operation: +; Mode "warm floors": +; Efficiency: 92.9 ;%; Nominal pressure inlet gas: 20 ;mbar; Max. the gas flow:...

Buderus Logamax U072-24K

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 192 ;m2; Useful power: 24 ;kW; The combustion chamber: open (chimney); Food: single-phase (220 V); Power consumption: 150 ;W; Min. t of the heating system: 40 ;°C; Max. t of the heating system: 82 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Max. the pressure in the DHW circuit: 10 ;bar; Min. t hot water: 40; Max. t hot water: 60; Summer operation: +; Nominal pressure inlet gas: 16 ;mbar; Max. the gas flow: 2.8 ;m3/hour; The capacity of the surge tank: 8 ;l;...

Bosch Gaz 4000 ZWA24-2K

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 180 ;m2; Useful power: 24 ;kW; The combustion chamber: open (chimney); Food: single-phase (220 V); Power consumption: 90 ;W; Min. t of the heating system: 38 ;°C; Max. t of the heating system: 85 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Max. the pressure in the DHW circuit: 10 ;bar; Min. t hot water: 40; Max. t hot water: 65; Performance (Δt=25°C): 17.1 ;l/min; Performance (Δt=35°C): 11.4 ;l/min; Summer operation: +; Nominal pressure inlet gas: 13 ;mbar; Max. the gas flow: 2.8 ;m3/hour;...