Heating boilers

Protherm Medved 30 KLOM

Source of energy: gas; Installation: outdoor; Type: dual circuit (heating and heating); Heating area: 199 ;m2; Built-in boiler: +; Useful power: 26.5 ;kW; The combustion chamber: open (chimney); Food: single-phase (220 V); Power consumption: 20 ;W; Min. t of the heating system: 45 ;°C; Max. t of the heating system: 90 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Min. t hot water: 37; Max. t hot water: 70; Performance (Δt=35°C): 14 ;l/min; Efficiency: 92 ;%; Nominal pressure inlet gas: 20 ;mbar; Max. the gas flow: 3 ;m3/hour; The diameter of the chimney: 130 ;mm; The water flow...

Buderus Logamax U072-18K

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 144 ;m2; Useful power: 18 ;kW; The combustion chamber: open (chimney); Food: single-phase (220 V); Power consumption: 130 ;W; Min. t of the heating system: 40 ;°C; Max. t of the heating system: 82 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Max. the pressure in the DHW circuit: 10 ;bar; Min. t hot water: 40; Max. t hot water: 60; Summer operation: +; Nominal pressure inlet gas: 16 ;mbar; Max. the gas flow: 2.1 ;m3/hour; The capacity of the surge tank: 8 ;l;...

Protherm Gepard 23 MOV

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 175 ;m2; Useful power: 23.3 ;kW; The combustion chamber: open (chimney); Food: single-phase (220 V); Power consumption: 92 ;W; Min. t of the heating system: 38 ;°C; Max. t of the heating system: 80 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Max. the pressure in the DHW circuit: 10 ;bar; Min. t hot water: 38; Max. t hot water: 60; Performance (Δt=25°C): 12.5 ;l/min; Summer operation: +; Efficiency: 90.3 ;%; Nominal pressure inlet gas: 20 ;mbar; Max. the gas flow: 2.73 ;m3/hour; The...

BAXI Eco Four 1.14 F

Source of energy: gas; Installation: wall; Type: single-circuit (only heating); Heating area: 105 ;m2; Useful power: 14 ;kW; The combustion chamber: closed (turbocharged); Food: single-phase (220 V); Power consumption: 120 ;W; Min. t of the heating system: 35 ;°C; Max. t of the heating system: 60 ;°C; Summer operation: +; Mode "warm floors": +; Efficiency: 92.5 ;%; Nominal pressure inlet gas: 20 ;mbar; The capacity of the surge tank: 6 ;l; The pressure of the surge tank: 0.5 ;bar; The diameter of the chimney: 60/100 ;mm / 80/80 for separate / ; Protection systems: The fall pressure gas Overheating...

Vaillant turboTEC plus VUW INT 362/3-5

Source of energy: gas; Installation: wall; Type: dual circuit (heating and heating); Heating area: 270 ;m2; Useful power: 36 ;kW; The combustion chamber: closed (turbocharged); Food: single-phase (220 V); Power consumption: 175 ;W; Max. t of the heating system: 85 ;°C; Max. the pressure in the heating circuit: 3 ;bar; Max. the pressure in the DHW circuit: 10 ;bar; Min. t hot water: 35; Max. t hot water: 65; Performance (Δt=25°C): 17.2 ;l/min; Summer operation: +; Efficiency: 93 ;%; Nominal pressure inlet gas: 20 ;mbar; Max. the gas flow: 4.4 ;m3/hour; The capacity of the surge tank: 10 ;l; The...